s88-N Feedback Module, 16-way

From 21,78 €

The s88-N Feedback Module, 16-way reports 16 inputs – for example from current sensors or turnout end-position sensors – to your command station via the s88-N bus.

At a glance

  • 16 inputs with spring terminals
  • For s88-N with 5 V or 12 V (variant selectable)
  • Connection via RJ45, expandable as required
  • 5 V supply (VCC) for sensors on board
  • Indicator LED for the power supply
Supply voltage
s88-N Rückmelder 16-fach mit Federklemmen für 16 Eingänge
1 × s88-N Feedback Module, 16-way – 5 V
21,78 €

34 in stock

s88-N Rückmelder 16-fach mit Federklemmen für 16 Eingänge
1 × s88-N Feedback Module, 16-way – 12 V
21,78 €

29 in stock

Matching s88-N cable
s88-N Kabel 25 cm, geschirmt, mit RJ45-Steckern in der Verpackung
1 × s88-N Cable – 25 cm
2,50 €

94 in stock

s88-N Kabel 50 cm, geschirmt, mit RJ45-Steckern in der Verpackung
1 × s88-N Cable – 50 cm
2,70 €

91 in stock

s88-N Kabel 100 cm, geschirmt, mit RJ45-Steckern in der Verpackung
1 × s88-N Cable – 100 cm
3,00 €

89 in stock

Mounting Kit
Befestigungsset mit vier Schrauben und vier Distanzhülsen
1 × Mounting Kit
1,50 €
Item no.: 02001
Category: ,
Brand:

How the s88-N Feedback Module, 16-way works

The feedback module collects the signals from up to 16 sensors – for example from current sensors for occupancy detection or from turnout end-position sensors – and passes them via the s88-N bus to your command station or an s88-N starting point. The modules are chained in series with RJ45 cables: the ‘Richtung Zentrale’ (towards the command station) socket points to the command station, and you connect the next feedback module to ‘Weitere Module’ (further modules).

5 V is available at the VCC terminals for sensors such as the Turnout End-Position Sensor. An LED shows whether the module is powered correctly. The Raildata signal of the s88-N bus is not used but is passed through, so that other modules in the chain can use it.

What else you need

Note: Please select the s88-N voltage (5 V or 12 V) to match your command station or starting point. All modules in a chain must have the same voltage.

Frequently asked questions

Do I need the 5 V or the 12 V variant?

That depends on your command station or s88-N starting point: depending on the device, the s88-N bus runs on 5 V or 12 V. All modules in a chain must be designed for the same voltage. The variant is marked on the back of the board.

How many feedback modules can I connect in a row?

The modules are chained in series with RJ45 cables and addressed consecutively. How many modules are possible depends on your command station or the s88-N starting point.

Is the feedback module also available with built-in current sensors?

Yes – the s88-N Occupancy Detector, 16-way combines 16 current sensors and the s88-N feedback module in a single module.

Technical data

Inputs

16

s88-N operating voltage

5 V or 12 V (note the marking on the board)

s88-N connector

RJ45

Feedback connection voltage

max. 35 V DC

VCC voltage (for sensors)

5 V

Connection

Spring terminals, up to 1.5 mm²

Operating temperature

−15 °C to +60 °C

Dimensions (L × W × H)

85 × 65 × 24.2 mm

Mounting holes

4 mm

s88-N timing

5 V: tpd 260 ns, tcycle ≥ 295 ns · 12 V: tpd 110 ns, tcycle ≥ 135 ns

Scope of delivery

1 s88-N Feedback Module, 16-way, 5 V or 12 V

Weight 43 g

Compatibility

For any command station with an s88-N connector or a separate s88-N starting point. Command stations with a classic s88 ribbon connector (e.g. ESU ECoS, Uhlenbrock Intellibox 1) are connected via the s88/s88-N Adapter. Our current sensors and the Turnout End-Position Sensor work on the inputs.

Product safety