16-fach Gleisbelegtmelder mit s88-N Rückmeldemodul

From 57,00 €

The s88-N Occupancy Detector, 16-way combines current sensors and an s88-N feedback module in one module: 16 track sections are monitored and reported directly to the command station via the s88-N bus.

At a glance

  • 16 detection sections in two groups of 8
  • Up to 3 A per group, also for two boosters
  • Current sensor and feedback module in one device
  • Sensitivity adjustable per output, spring terminals
  • Digital operation only
Mounting Kit
Befestigungsset mit vier Schrauben und vier Distanzhülsen
1 × Mounting Kit
1,50 €
Matching s88-N cable
s88-N Kabel 25 cm, geschirmt, mit RJ45-Steckern in der Verpackung
1 × s88-N Cable – 25 cm
2,50 €

94 in stock

s88-N Kabel 50 cm, geschirmt, mit RJ45-Steckern in der Verpackung
1 × s88-N Cable – 50 cm
2,70 €

91 in stock

s88-N Kabel 100 cm, geschirmt, mit RJ45-Steckern in der Verpackung
1 × s88-N Cable – 100 cm
3,00 €

89 in stock

61 in stock (can be backordered)

Item no.: 02004
Category: , ,
Brand:

How the s88-N Occupancy Detector, 16-way works

As soon as a vehicle draws current in any of the 16 monitored sections, the integrated current sensor detects the occupancy and reports it via the s88-N bus to your command station or your s88-N starting point. A separate current sensor module and additional wiring to the feedback module are no longer needed.

The 16 outputs are divided into two groups (1–8 and 9–16), each with its own input. The groups can be run from different boosters or together from one supply. You set the sensitivity for each output individually with a potentiometer. The detector is connected like an s88-N feedback module via two RJ45 sockets: ‘Richtung Zentrale’ (towards the command station) and ‘Weitere Module’ (further modules).

What else you need

  • an s88-N Cable for the connection to the command station or the next module
  • if your command station has a classic s88 connector: the s88/s88-N Adapter
  • for mounting: our Mounting Kit (selectable in the product options)

Note: The occupancy detector only works on digitally operated layouts; analogue operation is not supported. The current per group must not exceed 3 A, and short-circuit detection must be active on the command station or booster.

Frequently asked questions

Do I also need current sensors or a feedback module?

No. Current sensors and s88-N feedback module are already built into the module.

Can I connect two boosters?

Yes. The two groups 1–8 and 9–16 each have their own input and can be run from different boosters.

My command station has a classic s88 connector – will it still work?

Yes, with our s88/s88-N Adapter. The classic s88 ribbon connector is found on the ESU ECoS and the Uhlenbrock Intellibox 1, among others.

Technical data

Detection sections

16 (two groups of 8)

Max. total current per group

3 A

Max. current per output (track)

3 A

Max. voltage at track connection

35 V

s88-N connector

RJ45

Connection

Spring terminals, up to 1.5 mm²

Operating temperature

−15 °C to +60 °C

Dimensions (L × W × H)

120 × 85 × 24.2 mm

Mounting holes

4 mm

Scope of delivery

1 s88-N Occupancy Detector, 16-way

Compatibility

Gauge

H0TTNZ

Rail system

2-rail3-rail

Digital format

DCCMotorolamfxSelectrix

Reports directly via the s88-N bus to any command station with an s88-N connector or to an s88-N starting point. Command stations with a classic s88 ribbon connector (e.g. ESU ECoS, Uhlenbrock Intellibox 1) are connected via the s88/s88-N Adapter. On the track side, for boosters up to 3 A per group with short-circuit detection enabled.